Notes for the use of magnetic quick mold change templates:

Operation and maintenance by qualified personnel: Maintenance of electro-permanent magnetic quick mold change templates and their control systems shall be performed by professional technicians to guarantee stable operation and extended service life.
Electrical safety: Do not touch internal components of the electric controller with hands to prevent electric shock. Never touch push buttons or key switches with wet hands.
Strong magnetic field safety: The template generates strong magnetic fields. Persons with pacemakers are forbidden to approach it, as magnetic interference may cause pacemaker malfunction. When the template is engaged, keep ferrous materials away from the magnetic surface to avoid accidental attraction and injury.
Matching of molds and equipment: The mold size shall not be smaller than the minimum size specified in drawings to secure stable holding. The mold opening force and ejector force of the injection molding machine shall be set below 1/3 of the rated magnetic force of the template, and the ejector speed shall be limited to 50 mm/s to prevent mold falling or damage.
Cleaning and inspection: Clean the mating surfaces of molds and templates thoroughly before each mold change. Check mold flatness and eliminate air gaps between the mold and template to avoid magnetic loss.
Temperature control: Ensure mold temperature stays within the temperature rating of the template. Over-temperature operation will cause permanent damage.
Safety devices: Do not disable injection machine detection, mold detection or interlock controls under abnormal conditions. If a safety chain is equipped, fasten it after mold change to prevent mold dropping.
Operating specifications: Verify that the ejector holes of the mold match the machine and the ejector stroke is properly set to avoid mold falling. Never put hands or limbs into the machine during mold opening to prevent accidents.
Residual magnetism: A tiny amount of residual magnetism may remain on the template surface even in the demagnetized OFF state. Keep magnet-sensitive items away during operation.
Impact prevention: Avoid heavy mechanical impacts on the template and accessories to protect internal components from damage.

Compliance with the above rules ensures safe and efficient operation of the magnetic quick mold change template and prolongs its service life.